STRUCTURAL FRAME

Structural Frame

Object to measure: Structural Frame – Reinforced Concrete slab

Q.S to create complex recipe, with supporting graphics
30 Mpa Reinforced concrete slab average 300mm thick including concrete, formwork and reinforcement

30 MPa Reinforced concrete in slabs [Volume]
Use Revit volume of slab [Volume]
Formwork to soffit of slab [Area]
Use area of slab base [Area]
Formwork to edge of slab not exceeding 300mm high [Length]
Slab Edge Family [Perimeter]
Conventional bar reinforcement 150kg/m3 [kg]
Use volume of concrete slab

30 Mpa Reinforced concrete post tensioned slab average 275mm thick including concrete, formwork and reinforcement

30 MPa Reinforced concrete in flat slabs 275mm thick [Volume]
Use area of slab base
Formwork to soffit of slab exce 6.5 & n.e 8.0m [Area]
Use area of slab base
Rough formwork to edge of slab not exceeding 300mm high extreme [Length]
Slab Edge Family [Perimeter]
Conventional reinforcement at 14.0kg/m2 [kg]
Use area of slab base
Post tensioning reinforcement at 3.0kg/m2[kg]
Use area of slab base

Object to measure: Structural Frame – Reinforced Concrete Walls

30 Mpa Reinforced concrete Retaining wall 230mm thick including concrete, formwork and reinforcement

30 MPa Reinforced concrete in walls [Volume]
Use Revit volume
Formwork to sides of walls [Area]
Use Revit wall area
Conventional bar reinforcement 130kg/m3 [kg]
Use Revit volume

Object to measure: Structural Frame – Reinforced Concrete beams

30 Mpa Reinforced concrete downstand / inverted beam size 280 x 600mm (exce 5m & ne 6.5m high) including concrete, formwork and reinforcement

30 MPa Reinforced concrete in beams [Volume]
Use length of beams
Formwork to soffit of beams [Area]
Use length of beams
Formwork to sides of beams [Area]
Use length of beams
25x25mm chamfers to bottom edge of beam [length]
Use length of beams
Conventional bar reinforcement 120kg/m3
Use volume of beams

Object to measure: Structural Frame – Reinforced Concrete beams
30 Mpa Reinforced concrete upstand beam size 280 x 600mm (exce 5m & ne 6.5m high) including concrete, formwork and reinforcement

30 MPa Reinforced concrete in beams [Volume]
Use length of beams
Formwork to sides of beams [Area]
Use length of beams
Conventional bar reinforcement 120kg/m3
Use volume of beams

Object to measure: Structural Frame – Reinforced Concrete columns

30 Mpa Reinforced concrete column size 400 x 400mm (not exceeding 5m high) including concrete, formwork and reinforcement

30 MPa Reinforced concrete in columns [Volume]
Use height and number of columns
Formwork to sides of columns [Area]
Use height and number of columns
25x25mm chamfer to corner of column [length * 4]
Use height and number of columns
Conventional bar reinforcement 180kg/m3 [Volume * 180kg]
Use volume of columns

Object to measure: Structural Frame – Reinforced Concrete stairs

Reinforced concrete stair 3.95m long x 2.5m wide x 2.7m high

30 MPa Reinforced concrete in stair treads and risers [Volume]
Use length, height and number treads and risers
30 MPa Reinforced concrete in stairs landings [Volume]
Use area of landing slab
30 MPa Reinforced concrete in stairs waist [Volume]
Use length, thickness and width of waist
Formwork to soffit of stairs landing [Area]
Use area of landing slab
Formwork to raking stair soffit [Area]
Use length, height and number treads and risers
Formwork to edges of stair landing not exceeding 300mm high [Length]
Refer to drawing
Formwork to raking stair stringer not exceeding 300mm wide [Length]
Refer to drawing
Formwork to stair risers not exceeding 300mm high [Length]
Refer to drawing
Conventional bar reinforcement 180kg/m3 [Volume * 180kg]
Use volume of stair

Object to measure: Structural Frame – Reinforced Concrete Retaining Walls

30 Mpa Reinforced concrete Retaining wall 280mm thick including concrete, formwork and reinforcement, water protection lining, Geo drain, waterproofing to joints, etc

30 MPa Reinforced concrete in retaining walls
Use Revit volume
Formwork to sides of retaining walls
Use Revit area
Conventional bar reinforcement 150kg/m3
Use Revit volume
110mm Ǿ Geopipe wrapped in industex S120 laid to falls [Length]
Use Revit length
Provision for Netlon FlowNet type DN3 (wrapped in Industes S120) [Area]
Use Revit length
Provision for single layer Bituthene waterproof membrane to all cast joints in retaining walls (joints @ 5 000mm centres)
Use Revit area
Fibre cement sheet 6mm thick as protection to waterproofing installed loose in conjunction with back-filling
Use Revit area

Object to measure: Structural Frame – Structural Steel Columns, Beams

Welded columns in single lengths with flat section base, top, bearer and connection plates bolted to concrete

203 x 203mm x 46kg/m H section column [Tonnes]
Use Revit length and apply steel mass tables kg/m
Extra over structural steelwork for galvanizing [Tonnes]
Use Revit length and apply steel mass tables kg/m
175x170x10mm Thick base plate four times holed, 4-M16 bolts [Tonnes]
Use Revit number and apply steel mass tables kg/m2
M16 Chemical anchor bolts [Number]
Use Revit number
Patch prime defects with one coat zinc phosphate primer after erection, on Trusses, girders, bracing, etc. [Area]
Use Revit length and apply steel mass tables kg/m2
Prepare and apply 1 coat Universal undercoat and 2 coats Alkyd Gloss Enamel Trusses, girders, bracings, etc [Area]
Use Revit length and apply steel mass tables kg/m2
Vermiculite sprayed coating fire proofing to structural steelwork [Area]
Use Revit length and apply steel mass tables kg/m2

Welded beams in single lengths with flat section bearer and connection plates bolted to steel columns

254 x 146mm x 43kg/m I section beam [Tonnes]
Use Revit length and apply steel mass tables kg/m
10x 10mm thick stiffner [Tonnes]
Use Revit number and apply steel mass tables kg/m2
Patch prime defects with one coat zinc phosphate primer after erection, on Trusses, girders, bracing, etc. [Area]
Use Revit length and apply steel mass tables kg/m2
Prepare and apply 1 coat Universal undercoat and 2 coats Alkyd Gloss Enamel Trusses, girders, bracings, etc [Area]
Use Revit length and apply steel mass tables kg/m2
Vermiculite sprayed coating fire proofing to structural steelwork [Area]
Use Revit length and apply steel mass tables kg/m2

Advertisement

Leave a Reply

Fill in your details below or click an icon to log in:

WordPress.com Logo

You are commenting using your WordPress.com account. Log Out / Change )

Twitter picture

You are commenting using your Twitter account. Log Out / Change )

Facebook photo

You are commenting using your Facebook account. Log Out / Change )

Connecting to %s

Follow

Get every new post delivered to your Inbox.